MiCOM P540
|
|
MiCOM P541 - P546 RangeThe MiCOM P541-P546 series provides high-speed current differential unit protection. The P54x is designed for all overhead line and cable applications, as it interfaces readily with the longitudinal (end-end)communications channel between line terminals. The interface options support direct fiber optic, or multiplexed digital links.Optimum selectivity is assured, as the scheme measures the currents entering and leaving the protected plant item. Instantaneous tripping results for an internal fault, with stability for any out-of-zone fault. Tripping uses a proven characteristic comparing differential current with through current, for ease of testing. Phase differential elements of this type offer consistent detection of solid and resistive faults, with optimum faulted phase selection, tripping, and indication. A full range of back-up protection is integrated. This enhances the dependability of the protection, as hot-standby elements (such as distance zones and overcurrent) can be brought into service whenever a signalling channel outage may occur. Key Benefits
MiCOM P543 - P546 RangeThe MiCOM P543 to P546 is a range of transmission-class protection relays providing high-speed current differential unit protection. The P54x is designed for all overhead line and cable applications, as it interfaces readily with the longitudinal (end-end) communications channel between line terminals. The interface options support direct fiber optic, or multiplexed digital links.From design suffix K, a significant step evolution in the range has been introduced. P543 – P546 offer resident subcycle distance protection, to complement the powerful suite of main and backup protection already proven within the family. Full scheme, five zone distance protection is adopted from the class-leading MiCOMho P443. The P54x becomes the standard in all HV, EHV and UHV line protection applications, duplicated where dual redundant main protection is demanded. Set any combination of differential, distance, overcurrent, and reclosing, depending on the site needs. One universal relay type instead of two or more discrete models means reduced spares holding, less training, and lower cost. Breaker control and monitoring applicationThe MiCOM P544 & P546 is suitable for the complex installation and feeders controlled by two circuit breakers such as the breaker-and-a-half configurations. While MiCOM P543 & P545 are suitable for feeders controlled by single circuit breaker.Following features for Breaker control and monitoring applications are supported :
Key Benefits
Associated Training Courses
Current Differential Protection Relays
Current Differential Protection with Optional Subcycle Distance
MiCOM Protection 20, 30 and 40 Series Relays Key Features
Current Differential Protection - Software Version 20 and 30
Current Differential Protection - Software Version 20 and 30
Current Differential Relay - Software Versions 40 and 50 - P54x M/I64
Current Differential Relay - Software Versions 41 and 51
Current Differential Relay - Software Versions 45 and 55
Current Differential Relay - Software Versions 47 and 57
If you would like to receive a hard copy of a technical manual, please use our contact form and indicate which manual you would like to receive.
|




